# Dumping MyQ Home Bridge Keys Stops Offline Reboots

> An Arduino sketch reads the serial and AES-128 key from the MyQ 819LMB board so a local MQTT broker can spoof the cloud.

- Published: 2026-11-19T05:27:12Z
- Score: 7/10
- Tags: exploit, tool
- Web page: https://emu-radar.customfw.xyz/news/myq-819lmb-aes-key-dump-offline-mqtt/
- Sources: https://kusha.me/blog/stop_myq_homebridge_819lmb_rebooting/

Blocking the Chamberlain or LiftMaster MyQ Home Bridge (819LMB / MYQ-G0303) from the internet triggers watchdog reboots every 5 to 10 minutes on timeouts, or every 30 minutes even when local DNS returns TCP RST.

A write-up by Kusha Gharahi uses an [Arduino Script](https://github.com/kushagharahi/myq-homebridge-jailbreak/blob/main/myq_aes_dumper/myq_aes_dumper.ino) wired to the board's 10-pin Cortex-M4 debug pads to halt the CPU, scan flash for NVM routines, and dump the serial number and TLS-PSK AES-128 key. With those credentials, a local Mosquitto Docker container (`ghcr.io/kushagharahi/myq-homebridge-jailbreak:latest`) and local DNS spoofing for `connect.myqdevice.com` and `connect1.myqdevice.com` spoof the cloud MQTT connection.

1. Open the top shell (two screws) and wire Arduino pins D8 (SWDIO) and D9 (SWCLK) through 220 to 1000 ohm resistors to pads 2 and 4, plus ground.
2. Upload the dumper sketch in the Arduino IDE, read the serial and AES-128 key over Serial Monitor at 115200 baud, then run the Mosquitto container with `MYQ_SERIAL` and `MYQ_PSK`.
3. Point both myQ domains to the container host IP and check `/jabout` after 30 minutes to confirm `powered_time` is over 30 minutes with no reboot.

Use 220 to 1000 ohm resistors to protect the board from the Arduino's 5V pins.